webinar
Oct. 27-28, 2025, Boston, MA, USA - Booth 114.
Read More
LC-HRMS Testing

LC-HRMS Testing

At BOC Sciences, we offer comprehensive LC-HRMS testing services designed to meet the analytical needs of researchers and organizations across diverse industries. Our services include high-resolution analysis of small molecules, natural products, metabolites, and complex chemical compounds. Leveraging state-of-the-art instrumentation and an experienced analytical team, we provide accurate identification, structural elucidation, impurity profiling, and tailored data interpretation. Our clients consistently praise our precision, flexibility, and professional support. Whether you require routine testing or complex analytical solutions, BOC Sciences delivers reliable, high-quality results that empower informed scientific decision-making.

What is LC-HRMS Testing?

LC-HRMS (Liquid Chromatography–High Resolution Mass Spectrometry) testing is an advanced analytical approach that combines efficient separation with precise molecular detection. In this technique, liquid chromatography first separates complex mixtures into individual components based on properties such as polarity, molecular size, or hydrophobicity. The separated compounds are then ionized and analyzed by high-resolution mass spectrometry, which measures their mass-to-charge ratios with exceptional accuracy and sensitivity. This integration allows scientists to distinguish molecules with minute mass differences, reveal structural features, and perform reliable qualitative, quantitative, and impurity analyses. As a result, LC-HRMS has become a powerful tool for characterizing complex chemical and biological samples.

Specialized LC-HRMS Testing Services Options

Targeted Analysis LC-HRMS

We precisely quantify predefined target compounds, including metabolites, drugs, and natural products, using optimized LC-HRMS workflows. This approach ensures high sensitivity, reproducibility, and reliable results for research, residue detection, and environmental monitoring.

Non-Targeted Analysis LC-HRMS

We capture comprehensive chemical profiles without predefined targets, enabling discovery of unknown or novel compounds. Our advanced LC-HRMS acquisition and data processing provide accurate identification, supporting metabolomics, food safety, and unknown contaminant screening.

Suspect Screening LC-HRMS

We screen predefined lists of suspect compounds from databases or literature without requiring standards. Using high-resolution LC-HRMS, we efficiently detect potential contaminants, supporting food safety, environmental monitoring, and drug residue surveillance.

Need a Customized LC-HRMS Solution?

Tell us about your analytical requirements, and our experts will propose the optimal LC-HRMS workflow for your study.

Request a Quote

Sample Types Supported by Our LC-HRMS Testing

MTT Assay

Supported Sample Types

  • Small molecules: drugs, metabolites, natural products, environmental chemicals.
  • Biological samples: plasma, serum, urine, cell or tissue extracts.
  • Food and plant samples: extracts, beverages, supplements for compound profiling.
  • Chemical and material samples: intermediates, fine chemicals, functional materials.
CCK-8 Assay

Customer Sample Requirements

  • Sample form: liquid or dissolvable solids in compatible LC solvent.
  • Sample amount: typically 50–500 µL for liquids, 0.1–1 mg/mL for solids.
  • Solvent compatibility: water, methanol, acetonitrile, or low-concentration buffers.
  • Stability: store light- or heat-sensitive compounds at low temperature.
  • Safety information: provide MSDS for toxic, flammable, or corrosive substances.

LC-HRMS Testing – Sample Submission Form

Samples requiring LC-HRMS testing, with or without prior preparation, can be submitted using our Sample Submission Form.

Submit Your Sample

Advanced LC-HRMS Ionization Platform

Our LC-HRMS service platform offers a wide range of high-resolution mass spectrometry instruments equipped with various ionization sources, capable of analyzing compounds with diverse polarity and stability. This ensures precise identification, quantification, and advanced research applications. Key Capabilities Include:

Ionization SourceTarget CompoundsApplications
ESI-HRMS Polar or thermally labile molecules (metabolites, drugs, peptides)Ideal for sensitive biological and metabolomic analysis
APCI-HRMS Moderately polar small molecules (steroids, fat-soluble vitamins)Suitable for lipophilic compound quantification
APPI-HRMS Non-polar compounds (PAHs, petroleum additives)Efficient analysis of hydrophobic and aromatic molecules
nano-ESI-HRMS Low-volume samples, proteomics, single-cell metabolomicsNanoliter flow rates improve sensitivity for limited samples
HESI-HRMS Heated ESI, complex matrices such as oral liquidsEnhances desolvation efficiency for complex or viscous samples

LC-HRMS Testing Workflow for Accurate Analysis

Requirement Understanding

1Professional Consultation and Requirement Analysis

Clients submit sample information and testing goals online. Our experts provide tailored advice, ensuring the analysis plan meets specific project needs effectively.

Experimental Design

2Sample Receipt and Preparation

Upon plan confirmation, samples are received and logged under strict protocols. Necessary preparation ensures optimal conditions for accurate LC-HRMS analysis.

Model System Construction

3LC-HRMS Analysis

Our team performs high-sensitivity, high-precision analysis using advanced liquid chromatography–high resolution mass spectrometry systems, following rigorous laboratory standards.

Pharmacological Testing Execution

4Data Processing and Quality Control

Raw data is processed using specialized software. Multiple quality checks ensure reliable, consistent results, providing a solid foundation for reporting.

Data Collection and Analysis

5Professional Test Report Compilation

A structured report is generated, including clear methodology, visual data, and analysis results, enabling straightforward interpretation and application.

Report Delivery

6Report Delivery and Client Support

Final reports are securely delivered to clients. Our technical team provides ongoing support to answer questions and clarify analytical findings.

Contact Us to Accelerate Your LC-HRMS Testing Projects

BOC Sciences' LC-HRMS testing services deliver highly accurate mass analysis and structural characterization for diverse compounds, enabling efficient data acquisition and supporting the advancement of research and development initiatives.

Request a Quote

Precision HRMS Reports for Critical Data

Sample and Method Information

  • Sample ID, type, batch, and source.
  • Testing date and report issue date.
  • LC-HRMS method overview and conditions.
  • Laboratory and analyst information provided.

Analytical Results

  • Target compound detection and retention time.
  • Accurate mass (m/z) and peak intensity.
  • Quantitative concentration or relative abundance.
  • Unknown compound candidates with fragmentation data.

Quality Control and Data Visualization

  • Chromatograms (TIC/XIC) and mass spectra.
  • Standard curves and method calibration data.
  • Detection limits, recovery, and precision values.
  • Signal confirmation and error evaluation metrics.

Distinct Advantages of LC-HRMS Testing

Ultra-High-Resolution Detection

LC-HRMS precisely detects complex molecules, including low-abundance compounds, with mass measurement error typically within 2–5 ppm, ensuring highly reliable identification.

Comprehensive Structural Analysis

Provides in-depth insights into molecular structures and fragmentation patterns, delivering detailed information to support research and development decisions.

Flexible, Customized Workflows

Tailored LC-HRMS workflows are designed based on sample characteristics and analytical requirements, maximizing data quality across diverse sample types and complexities.

Advanced Data Interpretation

Combining cutting-edge software with sophisticated analytical strategies, complex high-resolution datasets are converted into actionable insights, accelerating project progress.

Applications for Pharmaceutical Research

BOC Sciences' LC-HRMS services support multiple application areas across drug discovery, preclinical development, and formulation, including but not limited to the following.

Preclinical Development

Formulation & Quality Control

LC-HRMS Testing Case Studies and Success Stories

Client: A leading environmental research institute in North America

Challenge: The client needed precise identification and quantification of trace-level organic pollutants in complex water and soil matrices, where traditional methods often failed to resolve overlapping compounds.

Solution: BOC Sciences implemented ultra-high-performance LC coupled with HRMS, utilizing optimized gradient elution methods and accurate mass detection. Our team tailored sample preparation protocols and applied advanced spectral deconvolution software to separate and quantify structurally similar contaminants.

Outcome: The client achieved highly reproducible detection of multiple pollutants, enhanced compound resolution, and received comprehensive reports with clear quantitative metrics, enabling data-driven environmental assessments.

Client: A global nutraceutical company

Challenge: The client required comprehensive profiling of complex botanical extracts to identify minor bioactive components while maintaining structural specificity and reducing analytical noise.

Solution: BOC Sciences deployed LC-HRMS with high-resolution Orbitrap analyzers and optimized electrospray ionization conditions. We developed custom chromatographic separation strategies and integrated full-scan and data-dependent MS/MS workflows to generate detailed molecular fingerprints of the extracts.

Outcome: The client obtained accurate molecular identification of both major and minor constituents, with high-confidence structural annotation, supporting product development and quality control initiatives.

Client: A leading biotechnology company focused on metabolic profiling

Challenge: The client needed sensitive and untargeted detection of a broad spectrum of endogenous metabolites in complex cell and tissue samples, with high dynamic range and minimal matrix interference.

Solution: BOC Sciences applied advanced LC-HRMS platforms with high-resolution time-of-flight (TOF) analyzers, using optimized polarity switching and automated data processing pipelines. Our team implemented robust internal standard strategies and spectral alignment techniques to ensure precise metabolite identification and quantification.

Outcome: The client achieved comprehensive metabolomic coverage, increased confidence in metabolite identification, and obtained high-quality, publication-ready datasets that supported key research initiatives and compound discovery programs.

Frequently Asked Questions

Client Reviews: LC-HRMS Testing Services

Related Services

Online Inquiry
Verification code