Inductively Coupled Plasma Optical Emission Spectrometry (ICP-OES): Principles, What It Measures, and Applications

Inductively Coupled Plasma Optical Emission Spectrometry (ICP-OES): Principles, What It Measures, and Applications

What Is ICP-OES?

Inductively coupled plasma optical emission spectrometry, commonly known as ICP-OES, is one of the most widely used techniques for elemental analysis in modern analytical laboratories. It measures the concentration of individual elements in a sample by atomizing the sample in a high-temperature argon plasma and detecting the characteristic light that excited atoms and ions emit as they return to lower energy states. The technique combines multi-element capability, a wide linear dynamic range spanning four to six orders of magnitude, and robust tolerance to complex sample matrices, making it suitable for applications that span pharmaceutical development, materials characterization, environmental monitoring, and chemical research. This article explains the principles behind ICP-OES, what it measures, its key applications, and the common challenges analysts face in daily practice, with practical guidance on how each is addressed.

Definition and Core Function of ICP-OES

ICP-OES stands for Inductively Coupled Plasma Optical Emission Spectrometry. The name captures the three pillars of the technique: the plasma is generated by electromagnetic induction in argon gas, the excited atoms and ions in that plasma emit light at wavelengths characteristic of each element, and a spectrometer resolves and measures that light to identify and quantify the elements present. In practice, a liquid sample is converted into a fine aerosol, transported into the plasma through the center of a quartz torch, and subjected to temperatures of 6,000 to 10,000 K. At these temperatures, the sample is completely desolvated, vaporized, atomized, and excited. As the excited atoms and ions relax to lower energy states, they emit photons whose wavelengths are unique to each element and whose intensities are proportional to the concentration of that element in the sample.

The core function of ICP-OES is elemental quantification: determining how much of each element is present in a sample. Unlike molecular techniques that identify compounds, ICP-OES answers the question of how much iron, copper, lead, sodium, or any other measurable element is in the material. This makes it complementary to organic analytical methods such as HPLC and GC, which characterize the molecular side of a sample, and to ion chromatography, which resolves individual ionic species. Together, these techniques form a complete analytical picture that development teams rely on to make informed decisions.

Table.1 ICP-OES Compared with Complementary Elemental Analysis Techniques.

TechniqueStrengthLimitation
ICP-OESMulti-element; wide linear range (4-6 orders); ppm to sub-ppb sensitivity; robust to high-matrix samples.Less sensitive than ICP-MS; spectral interferences possible in line-rich matrices.
ICP-MSUltra-trace sensitivity (ppt); isotope capability; wide element coverage.Matrix suppression at high dissolved solids; lower tolerance to TDS; higher instrument cost.
Flame AASSimple, cost-effective for single-element work; robust and widely available.Single-element sequential measurement; limited sensitivity; narrow linear range.
XRFNon-destructive; direct solid analysis; minimal sample preparation.Higher detection limits; surface-biased; lighter elements poorly detected.

How Does ICP-OES Work?

The previous section outlined the three analytical stages at a conceptual level. Here we follow the sample through the instrument in detail, from the moment it enters the nebulizer to the instant a concentration appears on the screen. Each step involves physical processes that the analyst can tune, and understanding these levers is the key to getting reliable data from difficult samples.

Sample Nebulization and Aerosol Transport

The sample introduction system is where most ICP-OES problems originate, and also where the most impactful improvements can be made. A peristaltic pump pushes the liquid sample into the nebulizer at a controlled flow rate, typically 0.5 to 2.0 mL per minute. The nebulizer converts this liquid stream into an aerosol using the energy of a high-velocity argon gas stream. Several nebulizer designs are in common use, each suited to different sample types:

  • Concentric nebulizers: the conventional choice for clean aqueous samples, offering efficient aerosol generation and low sample consumption.
  • Cross-flow nebulizers: more tolerant of high-salt and particulate-bearing samples, with a robust design that resists clogging.
  • Babington-type nebulizers: handle very high dissolved solids and suspended particles, making them suitable for the most challenging matrices.

The spray chamber sits between the nebulizer and the torch. Its function is to filter the aerosol: large droplets impact the chamber walls and drain to waste, while only the finest droplets are carried into the plasma. This matters because droplet size determines how completely the sample is desolvated and atomized. Cyclonic and double-pass Scott-type chambers are the two dominant designs, with cyclonic chambers offering slightly better transport efficiency and Scott-type chambers providing more stable signals for routine work.

Argon Plasma Generation and Element Excitation

The ICP torch is the heart of the instrument. It consists of three concentric quartz tubes: the outer tube carries the plasma (coolant) gas, the middle tube carries the auxiliary gas, and the inner tube carries the nebulizer gas with the sample aerosol. Argon flows through all three tubes, and a radio-frequency generator, typically operating at 27 or 40 MHz with 700 to 1,500 W of power, drives a current through a copper induction coil wound around the outer tube.

The plasma is initiated by a spark that strips electrons from argon atoms. These free electrons are accelerated by the oscillating RF field and collide with other argon atoms, creating a chain reaction that sustains a stable plasma. The temperature in the plasma core reaches 6,000 to 10,000 K, which is hot enough to completely break down any molecular bonds, atomize the sample, and excite both atoms and ions to higher energy states. The outer argon flow serves a dual purpose: it sustains the plasma and cools the quartz walls of the torch, preventing them from melting. The sample aerosol travels through the center of the plasma, where it experiences a residence time of a few milliseconds, long enough for complete desolvation, vaporization, atomization, and excitation to occur.

Characteristic Optical Emission from Excited Atoms and Ions

When excited atoms and ions in the plasma return to lower energy states, they emit photons at wavelengths characteristic of the specific element and the specific electronic transition involved. This emission is the analytical signal that ICP-OES detects. Each element produces multiple emission lines across the ultraviolet and visible spectrum, and the analyst selects the line that provides the best combination of sensitivity and freedom from spectral overlap. For example, an element like iron has thousands of emission lines, but a few, such as the 238.204 nm line, are commonly chosen because they offer high sensitivity with manageable interference from other elements.

The intensity of emission at a given wavelength is proportional to the number of atoms or ions of that element in the plasma, which in turn is proportional to the concentration in the original sample. This proportionality is the basis for quantification. Several factors influence the emission intensity beyond concentration alone, including plasma temperature, sample transport efficiency, and the degree of ionization. These variables are controlled through careful instrument tuning and compensated for through the use of internal standards, which are elements added at a known concentration to all samples and standards to correct for signal drift and matrix-induced signal suppression.

Wavelength Separation, Detection, and Quantification

After the light exits the plasma, it is collected by transfer optics and directed into the spectrometer. The spectrometer separates the polychromatic light into its component wavelengths using a diffraction grating or, in modern instruments, an Echelle grating cross-dispersed with a prism to produce a two-dimensional spectrum. This arrangement allows simultaneous measurement of multiple wavelengths, which is what gives ICP-OES its multi-element speed: a full suite of 20 to 40 elements can be measured in under two minutes per sample.

The detector measures the intensity of light at each selected wavelength. Solid-state detectors, such as CCDs and CIDs, have largely replaced photomultiplier tubes in modern instruments because they can measure many wavelengths simultaneously and offer a wide dynamic range. The raw signal is processed by software that subtracts background, applies inter-element corrections where needed, and converts the net intensity to a concentration using the calibration curve established with standards. The wide linear dynamic range of ICP-OES, typically four to six orders of magnitude, means that both trace-level and major-component elements can be quantified in the same analytical run, which is one of the key advantages over techniques with narrower linear ranges.

Need Accurate Elemental Data for Your Project?

From trace metal screening to multi-element quantification, our ICP-OES team delivers reliable results with rapid turnaround.

Get a Quote

What Does ICP-OES Measure? Elements and Analytes

ICP-OES is fundamentally a multi-element technique. A single analysis can quantify most metallic elements and several non-metals, covering concentration ranges from percentage levels down to low parts-per-billion. This breadth makes it a workhorse for any laboratory that needs to know what elements are in a sample and at what levels, and it explains why the technique appears in analytical programs across pharmaceutical, chemical, environmental, and materials fields.

Elemental Coverage Across the Periodic Table

ICP-OES can measure more than 70 elements across the periodic table, including all common metals, many semi-metals, and several non-metals. Alkali metals (Na, K, Li), alkaline earth metals (Ca, Mg, Ba, Sr), transition metals (Fe, Cu, Zn, Mn, Cr, Ni, Co, Mo, Pd, Pt, Ru, Rh), heavy metals (Pb, Cd, As, Hg, Sb), and main-group elements (Al, B, P, S, Si) are all routinely determined. The technique struggles with a few elements: halogens (F, Cl, Br, I) have emission lines in the deep UV and require specialized optics; noble gases are not measured because they are the plasma gas or do not emit efficiently; and elements such as C, N, and O are difficult because their emission lines fall in spectral regions contaminated by atmospheric absorption. For practical purposes, ICP-OES covers the elements that matter most to pharmaceutical, chemical, and materials laboratories, and Element Analysis programs built around the technique can address the vast majority of elemental questions that arise in development.

Trace Metal Analysis and Detection Limits

Detection limits are one of the primary specifications for any elemental technique, and ICP-OES occupies a useful middle ground between flame AAS and ICP-MS. For most metals, instrumental detection limits fall in the range of 0.1 to 10 µg/L (parts per billion), with some elements reaching sub-ppb levels under optimized conditions using axial plasma viewing. The actual detection limit achievable in a real sample depends on the matrix, the sample preparation procedure, and any dilution introduced during preparation. In complex matrices, practical quantification limits are typically higher than instrumental detection limits because of background contributions and dilution factors, and Heavy Metal Analysis programs must account for this gap when setting reporting thresholds.

Table.2 Representative Elements and Typical ICP-OES Detection Limits.

ElementCommon Wavelength (nm)Typical Detection Limit (µg/L)
Fe238.2040.5
Cu327.3930.3
Zn213.8560.2
Mn257.6100.1
Cr267.7160.5
Ni231.6040.5
Pb220.3531.0
Cd228.8020.3
As193.6962.0
Hg253.6525.0
Pd340.4581.0
Na589.5920.1
Ca317.9330.2
Al396.1520.3

These detection limits make ICP-OES suitable for most trace-level applications in pharmaceutical and chemical development. For ultra-trace determinations, such as very low-level heavy metal screening at sub-ppb concentrations, ICP-MS may be the better choice, and the two techniques are often used in complementary fashion within a single analytical program to match the sensitivity requirement of each target element.

Major, Minor, and Trace Element Quantification

One of the distinctive strengths of ICP-OES is its wide linear dynamic range. A single analytical run can quantify an element present at 10% of the sample and another at 10 ppb, without requiring separate dilutions. This means that major constituents, minor components, and trace impurities can all be reported from the same measurement, provided the calibration spans the necessary range and the selected wavelengths remain free from interference at both ends of the concentration scale. This capability is particularly valuable in Impurity Quantification programs, where a single method must cover both the trace-level impurities of interest and the major components that define the material.

In materials characterization, the same measurement that confirms a 5 ppm palladium residue from a hydrogenation catalyst can also report the 1000 ppm sodium from a neutralization step, provided the appropriate wavelengths and calibration ranges are selected. In alloy analysis, iron at 70%, chromium at 18%, manganese at 1%, and copper at 0.01% can all be determined in one ICP-OES run. This ability to span concentration ranges in a single analysis reduces the number of sample preparations, shortens turnaround time, and lowers the total cost of the analytical program.

Sample Matrices Compatible with ICP-OES Measurement

ICP-OES is designed for liquid samples, and any solid or semi-solid material must be dissolved before analysis. The technique handles a wide range of aqueous and acid-digested matrices, but the total dissolved solids (TDS) content matters: standard nebulizers and torches are typically rated for TDS up to 0.2-0.5%, and exceeding this limit can cause nebulizer clogging, salt deposition on the torch injector, and signal drift. High-TDS samples can be managed via dilution, via a high-solids nebulizer, or via a radial plasma view that tolerates matrix loads better than the axial view. Understanding which matrix preparation strategy to apply is central to Inorganic Impurities Analysis, because the preparation step often determines the quality of the final result as much as the instrument itself.

Table.3 Common Sample Matrices and Preparation Strategies for ICP-OES.

Sample MatrixPreparation StrategyKey Consideration
Aqueous solutions (water, process streams)Direct analysis or acidification with HNO3TDS typically low; minimal preparation needed; often compatible with axial viewing.
Organic solventsSolvent exchange or acid digestionCarbon buildup on torch; oxygen addition to outer gas may be needed.
Solid organics (APIs, polymers, food)Microwave-assisted acid digestion with HNO3Complete dissolution needed; closed-vessel digestion prevents volatile element loss.
Metals and alloysAcid dissolution with aqua regia or mixed acidsHigh acid concentration; may require significant dilution to protect the nebulizer.
Inorganic materials (ceramics, minerals)Alkali fusion or acid digestion with HFSilicate matrices may require HF; residual HF demands resistant introduction components.
Biological tissuesMicrowave digestion with HNO3/H2O2Organic matrix destruction; target low residual carbon to minimize background.

Looking for Multi-Element Analysis with Wide Linear Range?

ICP-OES delivers simultaneous quantification of major, minor, and trace elements in a single run, with robust performance across diverse sample types.

Get a Quote

Key Applications of ICP-OES

The combination of multi-element capability, wide dynamic range, and robust matrix tolerance makes ICP-OES a versatile tool across many fields. The applications below illustrate where the technique delivers the most value in pharmaceutical and chemical research, materials development, and process monitoring, with attention to the specific analytical questions each application answers.

Residual Metal Catalyst and Process-Related Element Analysis

Transition-metal catalysts are used extensively in pharmaceutical and fine-chemical synthesis, from hydrogenation (Pd, Pt, Ru) and cross-coupling (Pd, Ni, Cu) to oxidation (Cr, Mn, Ru) and olefin metathesis (Ru). After the reaction, these metals may remain in the product as residual impurities, and their quantification is a routine requirement in development and quality control. ICP-OES is well suited for this task because the target elements, typically Pd, Pt, Ru, Rh, Ir, Ni, Cu, and Cr, have strong emission lines and detection limits well below the levels at which they need to be controlled. The analytical procedure typically involves dissolving the sample, diluting to a suitable concentration, and measuring against matrix-matched standards. For difficult matrices, such as samples rich in organic content, microwave-assisted acid digestion with nitric acid and hydrogen peroxide provides a clean solution that introduces no metallic contaminants. Results are usually reported as µg/g of the element in the original material, and when integrated into a broader Process Impurities Analysis program, the data support both process optimization and impurity control in a single coordinated effort.

Elemental Profiling of APIs, Intermediates, Excipients, and Formulations

Beyond residual catalysts, ICP-OES contributes to the elemental chapter of a comprehensive impurity profile. Active pharmaceutical ingredients may carry trace metals from equipment contact, such as Fe, Cr, and Ni from stainless-steel processing surfaces; from raw materials, such as Pb, As, Cd, and Hg from mineral-derived reagents; or from packaging, such as Al and Ti from glass or coating materials. Excipients, though generally regarded as inert, can contribute ionic and metallic impurities that accumulate in the final product. Formulated materials, which combine API, excipients, and packaging, require elemental analysis that spans all of these sources. A typical profiling program applies a common ICP-OES method across starting materials, key intermediates, and the final API, revealing where metallic burdens enter the process and whether downstream operations reduce them. This longitudinal view supports route optimization and risk assessment in a way that end-product testing alone cannot. When combined with orthogonal techniques in a structured Impurity Profiling program, the elemental data complement organic impurity, residual solvent, and ionic impurity results to provide a complete inventory of what the sample contains.

Elemental Composition of Catalysts, Polymers, Ceramics, and Inorganic Materials

ICP-OES is equally valuable outside the pharmaceutical arena. In materials science, it characterizes the elemental composition of heterogeneous catalysts, where the active metal loading on a support material must be known accurately; of polymers, where residual catalysts from polymerization, additives, and fillers affect performance; and of ceramics and advanced inorganic materials, where stoichiometry and trace impurity levels define functional properties. The wide dynamic range is a particular advantage here: a catalyst may contain 5% palladium and 10 ppm iron, and both can be reported from a single measurement. For solid inorganic materials, sample preparation often involves alkali fusion or aggressive acid digestion to break down silicate or refractory matrices. In polymer analysis, microwave digestion with nitric acid in a closed vessel decomposes the organic matrix and releases metallic components into solution. The resulting data support quality control, lot-to-lot consistency evaluation, and failure analysis when a material does not perform as expected, making the technique an integral part of Polymer Impurity Analysis and broader materials characterization programs.

Nanoparticles, Drug Delivery Materials, and Functional Materials

Nanoparticle and drug delivery research increasingly requires elemental characterization. Metal-based nanoparticles, such as gold and silver particles used in diagnostic and therapeutic research, need accurate quantification of the metal core. Functionalized nanoparticles may carry surface-bound metals or inorganic tags whose loading must be determined. Liposomal and polymer-based drug delivery systems may incorporate trace metals from the manufacturing process. ICP-OES measures all of these with the sensitivity and dynamic range needed to cover both the active metal and trace contaminants. Sample preparation for nanoparticles depends on the matrix: metallic nanoparticles can often be dissolved in aqua regia, while polymer-stabilized particles may require acid digestion to release the metal. The results support formulation development, batch consistency, and the assessment of metallic impurities in nanomaterial products, complementing the physical characterization techniques that define particle size, surface charge, and morphology in Nanoparticle Synthesis and characterization workflows.

Water, Extract, and Process-Stream Element Analysis

ICP-OES began its life as a water analysis technique, and that application remains as relevant as ever. Process water, purified water, and effluent streams are monitored for metallic contaminants at levels far below those relevant in solid products. The high sensitivity of axial-view ICP-OES, combined with the clean matrix of water samples, makes this one of the simplest and most reliable applications of the technique. Beyond water, process streams, reaction mixtures, and cleaning-related samples are routinely analyzed. In cleaning verification, rinse water and surface swabs are screened for the metallic signature of previous products or catalyst residues, and their absence confirms the effectiveness of the cleaning cycle. Extractables and leachables studies, which assess the propensity of materials to release metallic species into solutions they contact, are another natural fit. The combination of multi-element capability and low detection limits means that a single ICP-OES run can screen for dozens of elements simultaneously, providing comprehensive coverage in a fraction of the time required by single-element techniques. This efficiency is why ICP-OES is a mainstay of Extractables and Leachables Testing and routine water monitoring programs.

Table.4 Representative ICP-OES Applications Across Sample Types.

Application AreaTarget ElementsAnalytical Value
Residual catalyst analysisPd, Pt, Ru, Rh, Ni, Cu, CrConfirms catalyst removal; supports process optimization and impurity control.
API and intermediate profilingFe, Cr, Ni, Pb, As, Cd, Hg, AlTracks metallic burdens across the synthetic route; identifies contamination sources.
Materials characterizationMajor and trace elements in alloys, ceramics, polymersDefines stoichiometry and purity; supports lot-to-lot consistency.
Nanoparticle and drug deliveryAu, Ag, Fe, Si, surface-tagged metalsQuantifies metal loading and trace contaminants in functional materials.
Water and process streamsFull multi-element panelsTrace-level monitoring; cleaning verification; extractables and leachables screening.

Need an ICP-OES Strategy for Your Research Sample?

Share your sample matrix, target elements, and expected concentration range with BOC Sciences. Our analytical team can help design a practical ICP-OES testing approach for elemental screening or targeted quantification.

Get a Quote

Common Challenges in ICP-OES Analysis and How to Solve Them

Despite its robustness, ICP-OES is not without challenges. Spectral interferences, matrix effects, sample introduction problems, and calibration drift can all compromise data quality if not recognized and addressed. The sections below describe each challenge and the practical solutions that experienced analysts apply to keep results accurate and defensible.

Spectral Interferences: Identification and Correction

Spectral interferences arise when the emission line of one element overlaps with that of another, causing the measured intensity at a given wavelength to include contributions from multiple species. This is most problematic in line-rich matrices, such as samples containing high concentrations of iron or rare-earth elements, where the density of emission lines increases the probability of overlap. There are three main types of spectral interference in ICP-OES:

Modern ICP-OES software automates much of this correction, but the analyst must still verify that the selected wavelengths are appropriate for the specific sample matrix. Running a scan of the spectral region around each analytical line, particularly for unfamiliar or complex samples, is the most reliable way to identify potential overlaps before they compromise results.

Matrix Effects and How to Overcome Them

Matrix effects refer to any non-spectral influence of the sample matrix on the measured signal. The most common are signal suppression caused by high dissolved solids, easily ionizable element effects that alter plasma characteristics, and viscosity differences between samples and standards that change the nebulization efficiency. These effects are minimized through several complementary strategies:

For particularly challenging matrices that defeat standard preparation, dedicated Challenging Sample Analytical Method Development services can design preparation and measurement protocols that address the specific interference profile of the material, from refractory ceramics to high-salt brines and concentrated organic matrices.

Sample Introduction Problems and Troubleshooting

The sample introduction system, comprising the peristaltic pump tubing, nebulizer, spray chamber, and drain, is the most maintenance-intensive part of the ICP-OES instrument. Most day-to-day problems originate here rather than in the plasma or optics. Common issues and their solutions include:

Discipline in maintenance is the single most effective way to minimize downtime. A well-maintained sample introduction system can run for days without intervention, while a neglected one will produce unreliable data and require frequent restarts.

Calibration Drift and Quality Control Strategies

ICP-OES signals can drift over the course of a long analytical run due to gradual changes in plasma conditions, nebulizer efficiency, or optics. Left uncorrected, this drift leads to inaccurate results that may not be apparent until the data are reviewed. Quality control practices that address drift include running an initial calibration verification standard from a different source immediately after calibration, analyzing a mid-range continuous calibration verification standard at regular intervals, monitoring the internal standard signal for each sample, and checking calibration blanks between samples for carryover and background contamination. When these practices are combined with Method Validation that establishes specificity, linearity, accuracy, precision, and robustness, the resulting data package is reliable and defensible. For programs requiring formal documentation, validated methods are transferred to client laboratories through structured transfer protocols that demonstrate equivalent performance at the receiving site.

BOC Sciences Support for ICP-OES and Elemental Analysis

BOC Sciences operates a dedicated ICP-OES capability within its broader analytical services platform, supporting pharmaceutical, biotechnology, materials, and fine-chemical clients from early research through commercial supply. Our ICP-OES laboratory combines modern simultaneous-spectrometer systems, experienced method development scientists, and a commitment to fitting the method to the analytical question rather than forcing the sample onto a generic protocol. Whether the need is a routine multi-element screen, a targeted quantification of residual catalysts, or a difficult low-level determination in a challenging matrix, projects are designed around the analytical target profile and executed with full documentation.

ICP-OES Testing for Targeted Quantification and Multi-Element Screening

Our core ICP-OES testing service covers the determination of metallic elements and selected non-metals across the full range of sample types described in this article. Standard multi-element panels are available for rapid turnaround on common needs, while custom panels extend coverage to specific elements or wavelength selections optimized for unusual matrices. Samples are accepted as APIs, intermediates, formulations, excipients, raw materials, catalysts, polymers, ceramics, nanoparticles, waters, swabs, and process streams, with preparation strategies, from simple dilution to microwave-assisted acid digestion and alkali fusion, selected to match the matrix. Every reported result is supported by calibration records, internal standard recovery data, and quality control charts, so that development teams can use the numbers with confidence.

Integrated Analytical Strategies for Elemental Characterization

Many elemental questions cannot be answered by ICP-OES alone. Our laboratory is structured to combine ICP-OES with complementary techniques within the broader Elemental & Material Analysis Technologies platform. For ultra-trace determinations, ICP-MS provides lower detection limits and isotope information; for molecular and structural questions, spectroscopic techniques and Structure Characterization provide complementary data; and for complete impurity assessment, organic, residual solvent, and ionic impurity results are integrated with elemental data into a single, coherent picture. Method development services design fit-for-purpose ICP-OES methods from first principles, beginning with the analytical target profile and proceeding through wavelength selection, interference assessment, and validation. Projects are managed with a single point of coordination and delivered as consolidated data packages through our Analytical Testing and Release service, so clients receive integrated results rather than a patchwork of disconnected reports.

Table.5 ICP-OES and Elemental Analysis Services at BOC Sciences.

Service NameDescriptionInquiry
ICP-OES TestingMulti-element quantification and screening across pharmaceutical, chemical, and material samples with wide linear range.Inquiry
ICP-MS TestingUltra-trace elemental analysis with isotope capability for sub-ppb determinations beyond ICP-OES sensitivity.Inquiry
Elemental & Material Analysis TechnologiesIntegrated platform combining ICP-OES, ICP-MS, and complementary techniques for comprehensive elemental characterization.Inquiry
Structure CharacterizationMolecular and structural analysis complementing elemental data for complete material understanding.Inquiry
Method Development, Validation and TransferFit-for-purpose ICP-OES method development with full validation and documented transfer to client laboratories.Inquiry
Analytical Testing and ReleaseIntegrated analytical testing programs delivering consolidated data packages across multiple techniques.Inquiry

Ready to Get Accurate Elemental Data?

Connect with our ICP-OES specialists to discuss your elemental analysis needs and receive a tailored analytical plan.